Super Usuario

Super Usuario

Isolating cardiomyocytes via Langendorff (retrograde) heart perfusion is known to yield the greatest number of cardiomyocytes compared to methods such as tissue dissection and manual dissociation. Harvard Apparatus is your source for the Hugo Sachs cardiomyocyte isolation systems, designed specifically to provide the tools necessary for obtaining high yields of sterile cardiomyocytes.

 

Hugo-Sachs Elektronik and Harvard Apparatus have always provided top-notch, fully integrated physiology research systems. Continuing our tradition of innovation and high performance we are happy to unveil the next generation Isolated Heart Perfusion System for Small Rodent models, the new IH-SR. The new IH-SR features an expanded range of measurement capabilities and ease of use which breaks new ground in ex-vivo cardiac research.

Jueves, 09 Enero 2014 12:56

Guide to Isolated Lung Perfusion Systems

The IPL method has been found to be invaluable in characterizing the non-respiratory capabilities of pulmonary tissues such as pulmonary metabolic activity as well as the activities of various components (pulmonary alveolar macrophage, alveolar tissue, endothelial tissue, etc) in response to inhaled/airborne particulates/therapies. Isolated lung systems are equally useful for evaluating respiratory functions such as respiratory mechanics and gas exchange.

Jueves, 09 Enero 2014 12:51

Neuroscience Applications Booklet

Harvard Apparatus and affiliates are cited over 850,000 times in 'Google Scholar', and over 10,000 times in 2012 alone. The following booklet contains examples of Harvard Apparatus products used in Neuroscience Research, along with summarizations of the experiments and related published articles.

Overview of Harvard Apparatus' complete anesthesia systems. Includes tabletop systems for active and passive scavenging, mobile systems for passive scavenging, and associated vaporizers and filter canisters.

 

Complete selection of Organ/Tissue Baths and Full Perfusion Systems. Twenty eight systems to choose from to meet your research needs. Staff scientists available for system consultations.

BTX offers a comprehensive line of instruments and accessories for both electroporation and electrofusion of mammalian, bacterial, yeast, fungi, insect and plant cells and tissues. BTX specializes in providing research tools for novel cutting edge applications such as adherent cell electroporation, high-throughput cloning, in vivo gene delivery, in ovo gene delivery, and in & ex utero gene delivery.

Miércoles, 08 Enero 2014 21:06

Estudios en tejidos u órganos aislados

The goal of a drug discovery effort is to generate novel, highly selective molecules that either inhibit or activate processes in the cell to ultimately produce therapeutic effects in humans. 

Miércoles, 08 Enero 2014 14:20

TERMÓMETRO DIGITAL (Panlab)

Panlab proposes two multi-channel digital thermometer models suitable for the measurement of animal body temperature using rectal probes. Both systems are designed for working with up to 12 resistive-temperature probes simultaneously.

Temperature is measured by using Yellow Springs (YSI) thermistor and the registered current value shown in the digital display of the front panel with a resolution of 0.1 degrees (sensitivity range: 32-45°C). There is no difference between channels or temperature probes, freely interchangeable. Standard YSI temperature probes should be plugged in the jack connectors of the rear panel, while the temperature value is read from the front panel display.

TMP812 model allows the reading of the current temperature of one channel at once. The selection is done by switching the desired channel in the 12-positions front panel rotary commuter.

TMP812RS model offers a 20x4 LCD display for showing the current temperature of all the probes at the same time. A built-in RS 232/USB communication port, allows sending (by pressing a front panel “SEND” button) the temperature values from all the probes to an external device (matrix printer with serial port or PC computer) through the SEDACOM software.

The new SEDACOM 2.0 version provides an easy and convenient way to visualize and export the data on a computer for further analysis.

 


Key features

  • Precalibrated and interchangeable probes
  • Options for Data transfer to a computer or printer

 


Specifications

Resolution

0,1 degrees Celsius

Capacity

Up to12 temperature probes simultaneously

Temperature probes

Standard YSI probes

Communications

RS232 (USB)

  


How to order 

CONTROL UNIT

TMP812RS

76-0065

12 Channels Digital Thermometer with RS232 port comms. Probes and SeDaCom software should be ordered separately.

 

TEMPERATURE PROBES

YS401

76-0066

Temperature probe for rabbits (3.9 mm)

YS402

76-0067

Temperature probe for rats & mice (3 mm)

YS451

76-0068

Temperature probe for mice (1.3 mm)

YS409

76-0069

Surface temperature probe (disc dia. 9.5 mm)

 

DATA TRANSFER & SOFTWARE

SEDACOM V2.0

76-0406

SeDaCom V2.0 software for data transfer to a computer

CONRS232USB

76-0608

SeDaCom accessory - RS232/USB adapter

  


Body temperature

See more information about body temperature evaluation in rodents in next link


 

Martes, 07 Enero 2014 20:12

ESTIMULADORES DIGITALES (Panlab)

Panlab provides a complete set of precise, compact and easy-to-use single-, double- or four-channels digital stimulators for general pharmacology and physiology such as organ/tissue bath studies. 

With a wide range of stimulation parameters, these stimulators offer an excellent and low priced alternative when single pulse and train stimulation is required.

 


Key features

  • Pulse and Train formation entirely controlled by Microprocessor
  • Allows stimulation of more than one isolated tissue preparation
  • Stimulation by Voltage and Current
  • Visual short-circuit security warning
  • Square-wave pulse
  • Built-in isolated output circuit (not related to ground)
  • Selected-parameters violation warning
  • Monopulse, Continuous and Train stimulations
  • TTL signal allowing for the external control of
  • DC Output
  • 125/220-50/60Hz power supply

 


Specifications

 

BASIC STIMULATOR LE12006

Number of Channels

1 channel

Pulse Frequency

0.01 - 99.99 Hz (0.01 Hz step)

Pulse Duration

0.1 - 9.9 ms (0.1 ms step)

OUTPUT Voltage

0 - 50 V (1 V resolution)

OUTPUT Max. Power

15 W (250 mA)

Accuracy

≤ 4% for timings and output

Power Supply

125/220V, 50/60Hz

 

PULSE GENERATOR

 

PULSE Frequency

1 Hz - 10 KHz (1 Hz step)

PULSE Duration

1 - 9999 μs (1 μs step); 1 - 9999 ms (1 ms step)

TRAIN Interval

0.1 - 999.9 s (1 s step)

TRAIN Duration

1 - 99.99 s (0.01 s step)

DIGITAL OUTPUT

5 V (TTL)

Accuracy

≤ 2% for timings and output

 

POWER UNIT

 

OUTPUT Voltage

0 - 100 V (1 V resolution); constant voltage (automated short circuit security)

OUTPUT Current

0 - 500 mA (5 mA resolution); constant current (automated short circuit security). Except for LE 12106: 0 - 100 mA (1 mA resolution); constant current (automated short circuit security)

OUTPUT Max

Power 50 W per channel (500 mA)

 

  


How to order 

 

COMPACT SYSTEMS

Dimensions (W x D x H)

LE12006

76-0061

1-Channel Basic Stimulator for teaching purpose

29 x 27 x 7 cm

LE12106

76-0055

1-Channel Digital Stimulator including 1 Pulse generator and 1 Power unit

34 x 31 x 15 cm

LE12206

76-0057

2-Channels Stimulator including 2 Pulse generators and 2 Power units

45 x 35 x 19 cm

LE12406

 76-0587

4-Channels Stimulator including 1 Pulse generator and 4 Power units

45 x 35 x 19 cm

 

MODULAR SYSTEMS

 

LE12406OM

76-0058

Power Unit module (LE12406TC needed)

7 x 12 x 17 cm

LE12406TC

76-0059

Pulse Generator & Mainframe module for up to 4 LE12406OM units

45 x 35 x 19 cm

LE12404

76-0060

Mainframe module for up to 4 LE12406OM units (External Pulse generator needed)

45 x 35 x 19 cm

LE12806

 

8-Channels Stimulator package including 1 LE12406TC, 1 LE12404 and 8 LE12406OM

2 x (45 x 35 x 19 cm)

 

OTHER ACCESSORIES

TRS081

76-0062

Nerve Electrode

TRS082

76-0063

Bipolar Electrode

 

  


Related products

  • Organ bath for teaching (P)
  • Organ bath for basic research (P)
  • Organ bath for advanced research (HS)

 


 

Página 12 de 26